{"title":"Variable Frequency Drives | VFD Inverter","description":"","products":[{"product_id":"1-5hp-lenze-smvector-n4x-vfd-208-240vac-1-or-3ph-input-indoor-outdoor-esv112n02yxe","title":"1.5HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input Indoor\/Outdoor  | ESV112N02YXE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input Indoor\/Outdoor | ESV112N02YXE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02YXE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Or Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor\/Outdoor","offer_id":43070877892656,"sku":"ESV112N02YXE","price":1084.48,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc.jpg?v=1779557928"},{"product_id":"1-5hp-lenze-smvector-nema1-vfd-400-480vac-3ph-input-esv112n04txb","title":"1.5HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input  | ESV112N04TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input | ESV112N04TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor","offer_id":43070878122032,"sku":"ESV112N04TXB","price":759.45,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc.jpg?v=1779557929"},{"product_id":"1-5hp-lenze-smvector-nema1-vfd-208-240vac-1-or-3ph-input-esv112n02yxb","title":"1.5HP Lenze SMVector NEMA1 VFD 208-240VAC 1 or 3PH Input  | ESV112N02YXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector NEMA1 VFD 208-240VAC 1 or 3PH Input | ESV112N02YXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02YXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Or Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor","offer_id":43070878154800,"sku":"ESV112N02YXB","price":664.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_62c962ce-314a-418e-93a1-af3492c7706a.jpg?v=1779557930"},{"product_id":"15hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-filtered-esv113n04tff","title":"15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered  | ESV113N04TFF","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered | ESV113N04TFF\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N04TFF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 24.0\/21.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070878187568,"sku":"ESV113N04TFF","price":4488.24,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_cf65d690-8683-4990-9772-07f41c047b7e.jpg?v=1779557930"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-esv112n04txe","title":"1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor  | ESV112N04TXE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor | ESV112N04TXE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TXE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070878842928,"sku":"ESV112N04TXE","price":1185.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_8fcc3439-69f3-4099-8ced-2f2f58a9f8e5.jpg?v=1779557932"},{"product_id":"15hp-lenze-smvector-n4x-vfd-208-240vac-3ph-input-indoor-outdoor-esv113n02txf","title":"15HP Lenze SMVector N4X VFD 208-240VAC 3PH Input Indoor\/Outdoor  | ESV113N02TXF","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 208-240VAC 3PH Input Indoor\/Outdoor | ESV113N02TXF\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N02TXF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 42.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 208-240(AC) \/ Indoor\/Outdoor","offer_id":43070878875696,"sku":"ESV113N02TXF","price":4055.31,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_ca552c73-cd0d-49e6-9d89-6e645aefb224.jpg?v=1779557932"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-disconnect-and-filtered-esv112n04tlc","title":"1.5HP LENZE SMVECTOR N4X VFD 400-480VAC 3PH Input Disconnect and Filtered | ESV112N04TLC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP LENZE SMVECTOR N4X VFD 400-480VAC 3PH Input Disconnect and Filtered | ESV112N04TLC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\/Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor","offer_id":43070879662128,"sku":"ESV112N04TLC","price":1494.22,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc.jpg?v=1779557935"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indoor-outdoor-esv112n01sxe","title":"1.5HP Lenze SMVector N4X VFD 120-240VAC 1PH Input Indoor\/Outdoor  | ESV112N01SXE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 120-240VAC 1PH Input Indoor\/Outdoor | ESV112N01SXE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N01SXE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 120-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 120-240(AC) \/ Indoor\/Outdoor","offer_id":43070879694896,"sku":"ESV112N01SXE","price":1312.83,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_f4d69c49-7541-49ec-ab61-1db48fa0ffab.jpg?v=1779557935"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-208-240vac-1-or-3ph-input-esv112n02yxc","title":"1.5HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input  | ESV112N02YXC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input | ESV112N02YXC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02YXC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Or Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor","offer_id":43070879760432,"sku":"ESV112N02YXC","price":957.67,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_e080ae06-bd2d-4bea-bb96-e64497ffa279.jpg?v=1779557935"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-esv112n04txc","title":"1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input  | ESV112N04TXC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input | ESV112N04TXC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TXC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor","offer_id":43070879793200,"sku":"ESV112N04TXC","price":1057.35,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_fd2078dc-1743-446d-9b7a-2bda5ae2f1d0.jpg?v=1779557935"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-esv112n01smc","title":"1.5HP Lenze SMVector N4X VFD 120-240VAC 1PH Input W\/ Disconnect | ESV112N01SMC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 120-240VAC 1PH Input W\/ Disconnect | ESV112N01SMC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N01SMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 120-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification \u003cbr\u003e• Lockable disconnect in CLOSED position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 120-240(AC) \/ Indoor","offer_id":43070880120880,"sku":"ESV112N01SMC","price":1496.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_f19cbdf1-817a-4d1f-8c91-44404aad9fe4.jpg?v=1779557936"},{"product_id":"15hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-filtered-esv113n04tfd","title":"15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Filtered  | ESV113N04TFD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Filtered | ESV113N04TFD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N04TFD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 24.0\/21.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 400-480(AC) \/ Indoor","offer_id":43070879858736,"sku":"ESV113N04TFD","price":4221.27,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_0a609ea4-65ba-46d5-90bb-672acefa4aa1.jpg?v=1779557936"},{"product_id":"1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-esv112n01sxb","title":"1.5HP Lenze SMVector NEMA1 VFD 120-240VAC 1PH Input  | ESV112N01SXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector NEMA1 VFD 120-240VAC 1PH Input | ESV112N01SXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N01SXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 120-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 120-240(AC) \/ Indoor","offer_id":43070879891504,"sku":"ESV112N01SXB","price":844.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_0c1ff0bd-f813-494b-ae4d-d348619444f1.jpg?v=1779557936"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-208-240vac-1-or-3ph-input-w-disconnect-esv112n02ymc","title":"1.5HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input W\/ Disconnect | ESV112N02YMC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input W\/ Disconnect | ESV112N02YMC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02YMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Or Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor","offer_id":43070882381872,"sku":"ESV112N02YMC","price":1268.41,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_f6ec1984-3a5d-496c-a98d-1c7ce1fa8843.jpg?v=1779557987"},{"product_id":"15hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-w-disconnect-esv113n04tmd","title":"15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input W\/ Disconnect | ESV113N04TMD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input W\/ Disconnect | ESV113N04TMD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N04TMD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 24.0\/21.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 400-480(AC) \/ Indoor","offer_id":43070882414640,"sku":"ESV113N04TMD","price":4055.31,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_ea49ce32-a823-4781-8d33-fbda221a7a51.jpg?v=1779557987"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-208-240vac-1ph-input-filtered-esv112n02sfc","title":"1.5HP Lenze SMVector N4X VFD 208-240VAC 1PH Input Filtered  | ESV112N02SFC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 208-240VAC 1PH Input Filtered | ESV112N02SFC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02SFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor","offer_id":43070882447408,"sku":"ESV112N02SFC","price":1044.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_e08f597c-5a87-4c14-bb95-6c292594227e.jpg?v=1779557987"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-w-disconnect-esv112n04tmc","title":"1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input W\/ Disconnect | ESV112N04TMC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input W\/ Disconnect | ESV112N04TMC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor","offer_id":43070882545712,"sku":"ESV112N04TMC","price":1367.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_d7f0f9ea-dcc5-4aa2-a4c8-0130c446b34b.jpg?v=1779557988"},{"product_id":"15hp-lenze-smvector-n4x-vfd-208-240vac-3ph-input-esv113n02txd","title":"15HP Lenze SMVector N4X VFD 208-240VAC 3PH Input  | ESV113N02TXD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 208-240VAC 3PH Input | ESV113N02TXD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N02TXD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 42.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 208-240(AC) \/ Indoor","offer_id":43070882480176,"sku":"ESV113N02TXD","price":3795.12,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_4fc73ceb-c77f-4294-ad3e-971615e500cb.jpg?v=1779557987"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-208-240vac-1ph-input-disconnect-and-filtered-esv112n02slc","title":"1.5HP LENZE SMVECTOR N4X VFD 208-240VAC 1PH Input Disconnect and Filtered | ESV112N02SLC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP LENZE SMVECTOR N4X VFD 208-240VAC 1PH Input Disconnect and Filtered | ESV112N02SLC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02SLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\/Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor","offer_id":43070882512944,"sku":"ESV112N02SLC","price":1353.2,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_32da2a6d-8407-41c6-911f-119ecb512f7c.jpg?v=1779557987"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-208-240vac-1ph-input-indoor-outdoor-filtered-esv112n02sfe","title":"1.5HP Lenze SMVector N4X VFD 208-240VAC 1PH Input Indoor\/Outdoor Filtered  | ESV112N02SFE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 208-240VAC 1PH Input Indoor\/Outdoor Filtered | ESV112N02SFE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N02SFE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 208-240(AC) \/ Indoor\/Outdoor","offer_id":43070882578480,"sku":"ESV112N02SFE","price":1169.83,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_4bf30158-089d-4562-a2ff-3e5b3aab290b.jpg?v=1779557987"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-filtered-esv112n04tfc","title":"1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Filtered  | ESV112N04TFC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Filtered | ESV112N04TFC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e:\u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor","offer_id":43070882611248,"sku":"ESV112N04TFC","price":1177.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_4f1d1d50-c458-4655-80eb-0b633a89c4cb.jpg?v=1779557987"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-filtered-esv112n04tfe","title":"1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered  | ESV112N04TFE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered | ESV112N04TFE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N04TFE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 3.5\/3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070882676784,"sku":"ESV112N04TFE","price":1306.46,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_1fc080c5-d179-4455-a324-54cad3e28048.jpg?v=1779557987"},{"product_id":"15hp-lenze-smvector-nema1-vfd-208-240vac-3ph-input-esv113n02txb","title":"15HP Lenze SMVector NEMA1 VFD 208-240VAC 3PH Input  | ESV113N02TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector NEMA1 VFD 208-240VAC 3PH Input | ESV113N02TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N02TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 42.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 208-240(AC) \/ Indoor","offer_id":43070882644016,"sku":"ESV113N02TXB","price":2722.5,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_1bc7eb3c-687c-4bac-94f6-60af3b2f2cbc.jpg?v=1779557987"},{"product_id":"15hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-disconnect-and-filtered-esv113n04tld","title":"15HP LENZE SMVECTOR N4X VFD 400-480VAC 3PH Input Disconnect and Filtered | ESV113N04TLD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP LENZE SMVECTOR N4X VFD 400-480VAC 3PH Input Disconnect and Filtered | ESV113N04TLD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N04TLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 24.0\/21.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\/Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 400-480(AC) \/ Indoor","offer_id":43070882709552,"sku":"ESV113N04TLD","price":4620.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_bfa44831-ecd3-4dd2-9632-99762ba3a254.jpg?v=1779557987"},{"product_id":"15hp-lenze-smvector-n4x-vfd-208-240vac-3ph-input-w-disconnect-esv113n02tmd","title":"15HP Lenze SMVector N4X VFD 208-240VAC 3PH Input W\/ Disconnect | ESV113N02TMD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 208-240VAC 3PH Input W\/ Disconnect | ESV113N02TMD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N02TMD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 42.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 208-240(AC) \/ Indoor","offer_id":43070882742320,"sku":"ESV113N02TMD","price":4620.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_b8f4785e-fc0e-4a9e-95d0-f789da59ef04.jpg?v=1779557988"},{"product_id":"15hp-lenze-smvector-nema1-vfd-400-480vac-3ph-input-esv113n04txb","title":"15HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input  | ESV113N04TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input | ESV113N04TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N04TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 24.0\/21.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 400-480(AC) \/ Indoor","offer_id":43070882775088,"sku":"ESV113N04TXB","price":2730.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_46b006dc-84c4-465f-93c6-158a8c9dd933.jpg?v=1779557988"},{"product_id":"20hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-disconnect-and-filtered-esv153n04tld","title":"20HP LENZE SMVECTOR N4X VFD 400-480VAC 3PH Input Disconnect and Filtered | ESV153N04TLD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP LENZE SMVECTOR N4X VFD 400-480VAC 3PH Input Disconnect and Filtered | ESV153N04TLD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N04TLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 31.0\/27.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\/Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 400-480(AC) \/ Indoor","offer_id":43070883201072,"sku":"ESV153N04TLD","price":6034.17,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_fe0f0f62-3c17-41cb-a446-e58e3fe8dd2e.jpg?v=1779557988"},{"product_id":"20hp-lenze-smvector-n4x-vfd-208-240vac-3ph-input-w-disconnect-esv153n02tmd","title":"20HP Lenze SMVector N4X VFD 208-240VAC 3PH Input W\/ Disconnect | ESV153N02TMD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector N4X VFD 208-240VAC 3PH Input W\/ Disconnect | ESV153N02TMD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N02TMD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 54.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 208-240(AC) \/ Indoor","offer_id":43070883233840,"sku":"ESV153N02TMD","price":5866.48,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_976a1b88-8f33-4143-b939-dcd88cc9c1ee.jpg?v=1779557989"},{"product_id":"2hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-esv152n04txc","title":"2HP Lenze SMVector N4X VFD 400-480VAC 3PH Input  | ESV152N04TXC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 400-480VAC 3PH Input | ESV152N04TXC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N04TXC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 4.0\/3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 400-480(AC) \/ Indoor","offer_id":43070883266608,"sku":"ESV152N04TXC","price":1145.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_8232d221-31b5-4304-8620-9c9a8a57d789.jpg?v=1779557989"},{"product_id":"2hp-lenze-smvector-n4x-vfd-480-600vac-3ph-input-indoor-outdoor-esv152n06txe","title":"2HP Lenze SMVector N4X VFD 480-600VAC 3PH Input Indoor\/Outdoor  | ESV152N06TXE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 480-600VAC 3PH Input Indoor\/Outdoor | ESV152N06TXE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N06TXE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 480-600(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 2.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 480-600(AC) \/ Indoor\/Outdoor","offer_id":43070883332144,"sku":"ESV152N06TXE","price":1373.33,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_a9e51efd-65f0-4b7b-af6a-5f48c4ea01b4.jpg?v=1779557990"},{"product_id":"2hp-lenze-smvector-n4x-vfd-480-600vac-3ph-input-esv152n06txc","title":"2HP Lenze SMVector N4X VFD 480-600VAC 3PH Input  | ESV152N06TXC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 480-600VAC 3PH Input | ESV152N06TXC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N06TXC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 480-600(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 2.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 480-600(AC) \/ Indoor","offer_id":43070883397680,"sku":"ESV152N06TXC","price":1255.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_3a02cb02-ea6d-4737-aff9-01f4efadbaa1.jpg?v=1779557990"},{"product_id":"2hp-lenze-smvector-nema1-vfd-480-600vac-3ph-input-esv152n06txb","title":"2HP Lenze SMVector NEMA1 VFD 480-600VAC 3PH Input  | ESV152N06TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector NEMA1 VFD 480-600VAC 3PH Input | ESV152N06TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N06TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 480-600(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 2.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 480-600(AC) \/ Indoor","offer_id":43070883364912,"sku":"ESV152N06TXB","price":899.09,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_9bc36bf1-f769-47cf-9023-3841453a0765.jpg?v=1779557990"},{"product_id":"2hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-esv152n04txe","title":"2HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor  | ESV152N04TXE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor | ESV152N04TXE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N04TXE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 4.0\/3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e:\u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070883528752,"sku":"ESV152N04TXE","price":1274.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_6e566d08-7b81-4464-b2f4-114cf0edf7c8.jpg?v=1779557990"},{"product_id":"20hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-filtered-esv153n04tfd","title":"20HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Filtered  | ESV153N04TFD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Filtered | ESV153N04TFD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N04TFD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 31.0\/27.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 400-480(AC) \/ Indoor","offer_id":43070883561520,"sku":"ESV153N04TFD","price":5601.33,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_f81a5418-9cdc-4a01-a688-8a74246db4bf.jpg?v=1779557990"},{"product_id":"2hp-lenze-smvector-n4x-vfd-480-600vac-3ph-input-w-disconnect-esv152n06tmc","title":"2HP Lenze SMVector N4X VFD 480-600VAC 3PH Input W\/ Disconnect | ESV152N06TMC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 480-600VAC 3PH Input W\/ Disconnect | ESV152N06TMC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N06TMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 480-600(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 2.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 480-600(AC) \/ Indoor","offer_id":43070883594288,"sku":"ESV152N06TMC","price":1563.87,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_bb272a31-a999-489b-944a-a6f7550f7b62.jpg?v=1779557991"},{"product_id":"2hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-filtered-esv152n04tfe","title":"2HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered  | ESV152N04TFE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered | ESV152N04TFE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N04TFE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 4.0\/3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070883627056,"sku":"ESV152N04TFE","price":1395.24,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_5db37315-fffe-4039-a2ae-ca629a009695.jpg?v=1779557991"},{"product_id":"20hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-w-disconnect-esv153n04tmd","title":"20HP Lenze SMVector N4X VFD 400-480VAC 3PH Input W\/ Disconnect | ESV153N04TMD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector N4X VFD 400-480VAC 3PH Input W\/ Disconnect | ESV153N04TMD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N04TMD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 31.0\/27.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 400-480(AC) \/ Indoor","offer_id":43070883659824,"sku":"ESV153N04TMD","price":5326.52,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_d326413e-4e06-4483-9c54-4ed58acefa28.jpg?v=1779557992"},{"product_id":"20hp-lenze-smvector-nema1-vfd-400-480vac-3ph-input-esv153n04txb","title":"20HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input  | ESV153N04TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input | ESV153N04TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N04TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 31.0\/27.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 400-480(AC) \/ Indoor","offer_id":43070883725360,"sku":"ESV153N04TXB","price":3346.45,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_eae19f79-6b69-4085-afd1-6740f0103a4e.jpg?v=1779557992"},{"product_id":"2hp-lenze-smvector-nema1-vfd-400-480vac-3ph-input-esv152n04txb","title":"2HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input  | ESV152N04TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector NEMA1 VFD 400-480VAC 3PH Input | ESV152N04TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N04TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 4.0\/3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 400-480(AC) \/ Indoor","offer_id":43070883889200,"sku":"ESV152N04TXB","price":810.09,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_88e33721-1b63-41f4-b92e-8f450266f813.jpg?v=1779557994"},{"product_id":"20hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-filtered-esv153n04tff","title":"20HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered  | ESV153N04TFF","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor Filtered | ESV153N04TFF\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N04TFF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 31.0\/27.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070883921968,"sku":"ESV153N04TFF","price":5890.68,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_24ee40ec-bf2f-4b2f-a5ea-6f60c7a6501c.jpg?v=1779557994"},{"product_id":"15hp-lenze-smvector-nema1-vfd-480-600vac-3ph-input-esv113n06txb","title":"15HP Lenze SMVector NEMA1 VFD 480-600VAC 3PH Input  | ESV113N06TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector NEMA1 VFD 480-600VAC 3PH Input | ESV113N06TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N06TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 480-600(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 17.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 480-600(AC) \/ Indoor","offer_id":43070883954736,"sku":"ESV113N06TXB","price":3007.43,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_2b1ef277-0507-4f54-bded-bc8d1740dc8b.jpg?v=1779557995"},{"product_id":"20hp-lenze-smvector-nema1-vfd-208-240vac-3ph-input-esv153n02txb","title":"20HP Lenze SMVector NEMA1 VFD 208-240VAC 3PH Input  | ESV153N02TXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector NEMA1 VFD 208-240VAC 3PH Input | ESV153N02TXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N02TXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 54.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 208-240(AC) \/ Indoor","offer_id":43070883987504,"sku":"ESV153N02TXB","price":3343.04,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_0ca5baf3-6114-4d76-8461-de2d155502e8.jpg?v=1779557996"},{"product_id":"2hp-lenze-smvector-n4x-vfd-208-240vac-1ph-input-disconnect-and-filtered-esv152n02slc","title":"2HP LENZE SMVECTOR N4X VFD 208-240VAC 1PH Input Disconnect and Filtered | ESV152N02SLC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP LENZE SMVECTOR N4X VFD 208-240VAC 1PH Input Disconnect and Filtered | ESV152N02SLC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N02SLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 7.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\/Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e:\u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 208-240(AC) \/ Indoor","offer_id":43070884020272,"sku":"ESV152N02SLC","price":1439.67,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_751a7128-2dfc-4520-8c62-f4aeefbc61e9.jpg?v=1779557995"},{"product_id":"20hp-lenze-smvector-n4x-vfd-208-240vac-3ph-input-indoor-outdoor-esv153n02txf","title":"20HP Lenze SMVector N4X VFD 208-240VAC 3PH Input Indoor\/Outdoor  | ESV153N02TXF","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector N4X VFD 208-240VAC 3PH Input Indoor\/Outdoor | ESV153N02TXF\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N02TXF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 54.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e:\u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 208-240(AC) \/ Indoor\/Outdoor","offer_id":43070884085808,"sku":"ESV153N02TXF","price":5433.6,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_4903818a-b7e8-4b68-8349-74feab94835f.jpg?v=1779557996"},{"product_id":"1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-esv112n01sxc","title":"1.5HP Lenze SMVector N4X VFD 120-240VAC 1PH Input  | ESV112N01SXC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e1.5HP Lenze SMVector N4X VFD 120-240VAC 1PH Input | ESV112N01SXC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV112N01SXC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 120-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz\u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"1.5 \/ 120-240(AC) \/ Indoor","offer_id":43070884053040,"sku":"ESV112N01SXC","price":1183.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_5c326c77-077c-4add-acfb-a9b55aa6a381.jpg?v=1779557996"},{"product_id":"20hp-lenze-smvector-n4x-vfd-208-240vac-3ph-input-esv153n02txd","title":"20HP Lenze SMVector N4X VFD 208-240VAC 3PH Input  | ESV153N02TXD","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e20HP Lenze SMVector N4X VFD 208-240VAC 3PH Input | ESV153N02TXD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV153N02TXD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 54.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional)\u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"20 \/ 208-240(AC) \/ Indoor","offer_id":43070884118576,"sku":"ESV153N02TXD","price":5175.15,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_03fa338e-5c01-402a-b492-d5497e6032f2.jpg?v=1779557996"},{"product_id":"2hp-lenze-smvector-n4x-vfd-208-240vac-1-or-3ph-input-w-disconnect-esv152n02ymc","title":"2HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input W\/ Disconnect | ESV152N02YMC","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 208-240VAC 1 or 3PH Input W\/ Disconnect | ESV152N02YMC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N02YMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Or Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 7.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integrated Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 208-240(AC) \/ Indoor","offer_id":43070884151344,"sku":"ESV152N02YMC","price":1350.86,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-w-disconnect-or-esv112n01smc-forces-inc_9788fc74-90c2-44dd-9284-f7acf579ebf3.jpg?v=1779557996"},{"product_id":"2hp-lenze-smvector-n4x-vfd-208-240vac-1ph-input-indoor-outdoor-filtered-esv152n02sfe","title":"2HP Lenze SMVector N4X VFD 208-240VAC 1PH Input Indoor\/Outdoor Filtered  | ESV152N02SFE","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector N4X VFD 208-240VAC 1PH Input Indoor\/Outdoor Filtered | ESV152N02SFE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N02SFE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 7.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Convection cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: Integral EMC Filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e:\u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection\u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 208-240(AC) \/ Indoor\/Outdoor","offer_id":43070884184112,"sku":"ESV152N02SFE","price":1255.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_c5101f6a-e87a-41b0-8f25-d6d26c7fa0a7.jpg?v=1779557997"},{"product_id":"15hp-lenze-smvector-n4x-vfd-400-480vac-3ph-input-indoor-outdoor-esv113n04txf","title":"15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor  | ESV113N04TXF","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-4_Brochure.pdf?v=1716826837\"\u003eInverter SMVector NEMA4X Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e15HP Lenze SMVector N4X VFD 400-480VAC 3PH Input Indoor\/Outdoor | ESV113N04TXF\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV113N04TXF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 400-480(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 24.0\/21.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X (IP65); Fan cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input\u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA\u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode\u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection\u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"15 \/ 400-480(AC) \/ Indoor\/Outdoor","offer_id":43070884249648,"sku":"ESV113N04TXF","price":3922.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-n4x-vfd-120-240vac-1ph-input-indooroutdoor-or-esv112n01sxe-forces-inc_517038d6-abee-47ec-aa8d-cd1746e00536.jpg?v=1779557996"},{"product_id":"2hp-lenze-smvector-nema1-vfd-208-240vac-1-or-3ph-input-esv152n02yxb","title":"2HP Lenze SMVector NEMA1 VFD 208-240VAC 1 or 3PH Input  | ESV152N02YXB","description":"\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_Manual.pdf?v=1716826827\"\u003eSMV Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0257\/7488\/2879\/files\/SMV_NEMA-1_Brochure.pdf?v=1716826835\"\u003eInverter SMVector NAME1 Flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProduct Details : \u003cstrong\u003e2HP Lenze SMVector NEMA1 VFD 208-240VAC 1 or 3PH Input | ESV152N02YXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No\u003c\/strong\u003e: ESV152N02YXB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Lenze Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SMVector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 208-240(AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Phase\u003c\/strong\u003e: Single Or Three Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Phase\u003c\/strong\u003e: 3 Phase Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Amperage\u003c\/strong\u003e: 7.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 1(IP31)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Filter\u003c\/strong\u003e: No EMC Filter\/ No Disconnect Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e: \u003cbr\u003e• Features : Dynamic Torque Response Two Independent Accel Ramps and two Independent Decel Ramps Linear, S-Type, Auxiliary Ramp-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency (1,000 Hz Optional) \u003cbr\u003e• Switching Frequency : 4, 6, 8, 10,12 or 16 kHz \u003cbr\u003e• Universal Logic Assertion (Selectable): Positive or Negative Logic Input \u003cbr\u003e• Braking Functions : DC Injection Braking Optional Regenerative Braking Over Temperature Protection \u003cbr\u003e• Speed Commands : Keypad Potentiometer Jog Floating Point Control \u0026amp; 8 Preset Speeds Voltage: Scalable 0 - 10 VDC Current: Scalable 4 - 20 mA \u003cbr\u003e• Process Control : PID Modes: Direct and Reverse Acting, sleep mode \u003cbr\u003e• Voltage Monitoring : High - Low DC Bus V Protection Low Line V Compensation \u003cbr\u003e• Current Monitoring : Motor Overload Protection Current Limiting Safeguard Phase Loss Protection Ground Fault Short Circuit Protection \u003cbr\u003e• Loss of Follower Management : Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor any information about products, please contact us.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e*Photos for reference purposes only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Forces Inc","offers":[{"title":"2 \/ 208-240(AC) \/ Indoor","offer_id":43070884216880,"sku":"ESV152N02YXB","price":721.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/files\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_651e6120-9757-49de-8df8-737ba3cc592c.jpg?v=1779557996"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/0768\/5936\/collections\/1-5hp-lenze-smvector-nema1-vfd-120-240vac-1ph-input-or-esv112n01sxb-forces-inc_426f6be1-2f62-4dca-8f74-722a53739840.jpg?v=1776062474","url":"https:\/\/infinitesupplyandservices.com\/collections\/variable-frequency-drives-vfd-inverter.oembed","provider":"INFINITE SUPPLY \u0026 SERVICES INC","version":"1.0","type":"link"}